| Sign In | Join Free | My gastesters.com |
|
Brand Name : Endress+Hauser
Certification : CE
Place of Origin : Switzerland
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Model Number : Proline t-mass A 150
Transmitter housing material : AlSi10Mg, coated
Degree of protection : IP66/67, type 4X enclosure
Display/Operation : 4‐line display with push Buttons
Outputs : 4‐20 mA HART (active)
Digital communication : HART
"Specs at a glance
Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature ""Calibration flow"")
Measuring range
0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature ""Calibration flow"")
Medium temperature range
–40 to +100 °C (–40 to +212 °F)
Max. process pressure
PN 40, Class 300
Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L)" "Field of application
The t-mass A 150 inline device is specially designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. its 4-wire technology is contained within a rugged compact aluminum housing. It is orderable either with display or as a blind version. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Device properties
Inline version: nominal diameter DN 15 to 50 (1/2 to 2"")
Process pressure up to PN 40, Class 300
A variety of process connections available
Device in compact version with DC 24 V power supply
4-20 mA HART, pulse/frequency/switch output
Compact and robust transmitter" "Benefits
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes
Optimal process monitoring – easy measurement even at low pressures and flow velocities
Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
Reliable flow trending – multivariable measurement
Fast and efficient commissioning – guided operating menus
High plant availability – self-diagnostics and error monitoring
Automatic recovery of data for servicing" "Measuring principle
Thermal
Product headline
The flowmeter for cost-effective measurement and easy monitoring of utility gases.
Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Sensor features
Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement.
Inline version: DN 15 to 50 (½ to 2""). Process pressure up to PN 40, Class 300. A variety of process connections available.
Transmitter features
Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing.
Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter.
Nominal diameter range
DN 15 to 50 (½ to 2"")
Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L)
Measured variables
Mass flow, temperature, corrected volume flow, FAD volume flow
Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature ""Calibration flow"")
Measuring range
0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature ""Calibration flow"")
Max. process pressure
PN 40, Class 300
Medium temperature range
–40 to +100 °C (–40 to +212 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Transmitter housing material
AlSi10Mg, coated
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
4‐line display with push Buttons
Configuration via local display and operating tools possible
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
Status input
Digital communication
HART
Power supply
DC 18 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
PED, CRN"
|
|
Proline t-mass A 150 thermal mass flowmeter Images |